What is an IP and NEMA rating?

In this article:

  1. What’s the difference between NEMA and IP Ratings?
  2. Overview of NEMA Ratings Applicable to Assured Products
  3. Overview of IP Ratings Applicable to Assured Products
  4. IP ratings are distinguished by two numbers.
  5. Comparing IP65 vs NEMA4X
  6. IP Rating Reference Chart
  7. How are industrial computers and displays NEMA or IP Certified ?

What’s the difference between NEMA and IP Ratings?

Industrial computers and displays are rated/certified in terms of their level of protection against damage from water, dust and other foreign objects, in terms of IP  and NEMA ratings.

IP and NEMA ratings specify the standard of protection against the ingress of liquid and solid objects, primarily dust.

While NEMA and IP ratings are not identical, they are very similar and can often be used interchangeably for the purpose of rating enclosures for industrial environments.

NEMA ratings go a step further and specify protection against the presence of corrosive agents.

NEMA ratings were developed by the U.S. National Electrical Manufacturers Association.

Ingress Protection ratings, commonly known as IP ratings, were developed in Europe and are internationally recognised.

Overview of NEMA Ratings Applicable to Assured Products

The U.S. based National Electrical Manufacturers Association (NEMA), provides a rating system to classify industrial enclosures based on their ability to protect users from internal electronics and internal electronics from the external environment.

NEMA ratings only apply to products going to North America.

Their are 20 different types of NEMA enclosure ratings standards ranging from the most basic level of protection against solid objects, to full submersion, to containing internal explosions.

Assured Systems mainly supply industrial computers and displays with the three NEMA ratings, NEMA 12, NEMA 4, and NEMA 4X.

NEMA 12 Rated

NEMA 12 rated industrial computers and displays are designed and manufactured for indoor use and provide a degree of protection to the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibres, and flyings) and provide a degree of protection with respect to harmful effects on the equipment, due to the ingress of water (dripping and light splashing).

NEMA 4 Rated

NEMA 4 rated industrial computers or displays are designed and manufactured for either indoor or outdoor and provide a degree of protection to the the equipment inside the enclosure against ingress of solid foreign objects such as dust and provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water).

NEMA 4X Rated

NEMA 4X rated Industrial computers and displays are manufactured with all the protection of the NEMA 4 rating plus protection against corrosion of the enclosure. Industrial panel computers and displays with this rating are typically constructed of high-grade stainless steel.

This information can be summarised in the table below:

Protection Against: NEMA 2 NEMA 12 NEMA 4 NEMA 4X
Ingress of water (dripping or light splashing) X X X X
Ingress of solid foreign objects (windblown dust, lint, fibres, and flyings) X X X
Ingress of water (rain, snow, and sleet) X X
Ingress of water (hose down) X X
Corrosive agents

Overview of IP Ratings Applicable to Assured Products

Ingress ratings, or IP ratings, are standards for the degree of protection an electrical enclosure such as an industrial computer or display provides against the ingress of foreign objects such as dust and water.

IP ratings are distinguished by two numbers.

The first digit in the IP rating indicates the enclosure’s ability to protect against the ingress of foreign solid objects, such as dust; the second digit indicates the level of protection against the ingress of water or other liquids.

Assured Systems typically supply industrial computers and displays with four different IP ratings: IP54, and IP65/IP66/IP69K.

First Digit:

Protection against foreign objects: Number
Dust protected, limited ingress 5
Dustproof, no ingress 6

Second Digit:

Protection against water: Number
No protection 0
Water sprayed up to 15° from vertical 2
Water sprayed, any direction 4
Water projected by low pressure water jets, any direction 5
Water projected by high pressure water jets, any direction 6

Comparing IP65 vs NEMA4X

This chart gives an approximate comparison of the IP and NEMA ratings used by Assured Systems:

NEMA Rating (U.S.) IP Rating (International)
12 IP54
4 IP65 ⁄ IP66
4X IP65 ⁄ IP66 / IP69K

IP Rating Reference Chart

IP Rating First Digit – SOLIDS Second Digit – LIQUIDS
IP00 Not protected from solids. Not protected from liquids.
IP01 Not protected from solids. Protected from condensation.
IP02 Not protected from solids. Protected from water spray less than 15 degrees from vertical.
IP03 Not protected from solids. Protected from water spray less than 60 degrees from vertical.
IP04 Not protected from solids. Protected from water spray from any direction.
IP05 Not protected from solids. Protected from low pressure water jets from any direction.
IP06 Not protected from solids. Protected from high pressure water jets from any direction.
IP07 Not protected from solids. Protected from immersion between 15 centimetres and 1 metre in depth.
IP08 Not protected from solids. Protected from long term immersion up to a specified pressure.
IP10 Protected from touch by hands greater than 50 millimetres. Not protected from liquids.
IP11 Protected from touch by hands greater than 50 millimetres. Protected from condensation.
IP12 Protected from touch by hands greater than 50 millimetres. Protected from water spray less than 15 degrees from vertical.
IP13 Protected from touch by hands greater than 50 millimetres. Protected from water spray less than 60 degrees from vertical.
IP14 Protected from touch by hands greater than 50 millimetres. Protected from water spray from any direction.
IP15 Protected from touch by hands greater than 50 millimetres. Protected from low pressure water jets from any direction.
IP16 Protected from touch by hands greater than 50 millimetres. Protected from high pressure water jets from any direction.
IP17 Protected from touch by hands greater than 50 millimetres. Protected from immersion between 15 centimetres and 1 metre in depth.
IP18 Protected from touch by hands greater than 50 millimetres. Protected from long trem immersion up to a specified pressure.
IP20 Protected from touch by fingers and objects greater than 12 millimetres. Not protected from liquids.
IP21 Protected from touch by fingers and objects greater than 12 millimetres. Protected from condensation.
IP22 Protected from touch by fingers and objects greater than 12 millimetres. Protected from water spray less than 15 degrees from vertical.
IP23 Protected from touch by fingers and objects greater than 12 millimetres. Protected from water spray less than 60 degrees from vertical.
IP24 Protected from touch by fingers and objects greater than 12 millimetres. Protected from water spray from any direction.
IP25 Protected from touch by fingers and objects greater than 12 millimetres. Protected from low pressure water jets from any direction.
IP26 Protected from touch by fingers and objects greater than 12 millimetres. Protected from high pressure water jets from any direction.
IP27 Protected from touch by fingers and objects greater than 12 millimetres. Protected from immersion between 15 centimetres and 1 metre in depth.
IP28 Protected from touch by fingers and objects greater than 12 millimetres. Protected from long term immersion up to a specified pressure.
IP30 Protected from tools and wires greater than 2.5 millimetres. Not protected from liquids.
IP31 Protected from tools and wires greater than 2.5 millimetres. Protected from condensation.
IP32 Protected from tools and wires greater than 2.5 millimetres. Protected from water spray less than 15 degrees from vertical.
IP33 Protected from tools and wires greater than 2.5 millimetres. Protected from water spray less than 60 degrees from vertical.
IP34 Protected from tools and wires greater than 2.5 millimetres. Protected from water spray from any direction.
IP35 Protected from tools and wires greater than 2.5 millimetres. Protected from low pressure water jets from any direction.
IP36 Protected from tools and wires greater than 2.5 millimetres. Protected from high pressure water jets from any direction.
IP37 Protected from tools and wires greater than 2.5 millimetres. Protected from immersion between 15 centimetres and 1 metre in depth.
IP38 Protected from tools and wires greater than 2.5 millimetres. Protected from long term immersion up to a specified pressure.
IP40 Protected from tools and small wires greater than 1 millimetre. Not protected from liquids.
IP41 Protected from tools and small wires greater than 1 millimetre. Protected from condensation.
IP42 Protected from tools and small wires greater than 1 millimetre. Protected from water spray less than 15 degrees from vertical.
IP43 Protected from tools and small wires greater than 1 millimetre. Protected from water spray less than 60 degrees from vertical.
IP44 Protected from tools and small wires greater than 1 millimetre. Protected from water spray from any direction.
IP45 Protected from tools and small wires greater than 1 millimetre. Protected from low pressure water jets in any direction.
IP46 Protected from tools and small wires greater than 1 millimetre. Protected from high pressure water jets from any direction.
IP47 Protected from tools and small wires greater than 1 millimetre. Protected from immersion between 15 centimetres and 1 metre in depth.
IP48 Protected from tools and small wires greater than 1 millimetre. Protected from long term immersion up to a specified pressure.
IP50 Protected from limited dust ingress. Not protected from liquids.
IP51 Protected from limited dust ingress. Protected from condensation.
IP52 Protected from limited dust ingress. Protected from water spray less than 15 degrees from vertical.
IP53 Protected from limited dust ingress. Protected from water spray less than 60 degrees from vertical.
IP54 Protected from limited dust ingress. Protected from water spray from any direction.
IP55 Protected from limited dust ingress. Protected from low pressure water jets from any direction.
IP56 Protected from limited dust ingress. Protected from high pressure water jets from any direction.
IP57 Protected from limited dust ingress. Protected from immersion between 15 centimetres and 1 metre in depth.
IP58 Protected from limited dust ingress. Protected from long term immersion up to a specified pressure.
IP60 Protected from total dust ingress. Not protected from liquids.
IP61 Protected from total dust ingress. Protected from condensation.
IP62 Protected from total dust ingress. Protected from water spray less than 15 degrees from vertical.
IP63 Protected from total dust ingress. Protected from water spray less than 60 degrees from vertical.
IP64 Protected from total dust ingress. Protected from water spray from any direction.
IP65 Protected from total dust ingress. Protected from low pressure water jets from any direction.
IP66 Protected from total dust ingress. Protected from high pressure water jets from any direction.
IP67 Protected from total dust ingress. Protected from immersion between 15 centimetres and 1 metre in depth.
IP68 Protected from total dust ingress. Protected from long term immersion up to a specified pressure.
IP69K Protected from total dust ingress. Protected from steam-jet cleaning.

How are industrial computers and displays NEMA or IP Certified ?

NEMA ratings and IP ratings are both self-certified. This means that any manufacturer can design and manufacture a product to a particular rating and specify that it’s rated to that particular NEMA or IP rating, without any approval or certification from an outside agency.

Assured System’s partners with global leaders in the design and manufacture of IP65 panel computers and IP65 displays who conform to the highest standards when performing NEMA and ingress protection testing.

Do you need further assistance?